BF510
Body Composition Monitor
EN
FR
DE
IT
• Instruction Manual
• Mode d’emploi
• Gebrauchsanweisung
• Manuale di istruzioni
• Manual de instrucciones
• Gebruiksaanwijzing
ES
NL
RU
AR
•
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
Thank you for purchasing the OMRON Body Composition Monitor.
Before using this unit for the first time, please be sure to read this Instruction Manual
carefully and use the unit safely and properly.
Please keep this Instruction Manual at hand all the time for future reference.
IM-HBF-510-E-04-08/08
1665710-1D
Before using the unit
BF510
Body Composition Monitor
Please read instructions carefully before use, and keep this manual for future reference. Do not use this unit for
purposes other than described in this manual.
Contents
4. Taking a Measurement ................................. 7
5. Measuring Weight Only.............................. 10
Before using the unit
Notes on Safety.................................................. 1
Useful Information ............................................. 2
Care and maintenance
6. Error Displays ..............................................11
7. Troubleshooting...........................................11
8. How to Take Care of and Store the Unit.... 12
9. Technical Data............................................. 13
Operating instructions
1. Know Your Unit ............................................. 4
2. Inserting and Replacing the Batteries ........ 4
3. Setting and Storing Personal Data.............. 5
Notes on Safety
Symbols and definitions are as follows:
Improper use may cause danger resulting in death or serious injury.
Improper use may result in possible death or serious injury.
Improper use may result in injury or property damage.
• If battery fluid should get in your eyes, immediately
Danger:
Warning:
Caution:
Danger:
rinse with plenty of clean water. Consult a doctor
immediately.
• Never use this unit in combination with medical
electronic devices such as:
(1) Medical electronic implants such as
pacemakers.
Caution:
• Do not disassemble, repair, or remodel the display
(2) Electronic life support systems such as
an artificial heart/lung.
unit or the main unit.
• Do not use a cellular phone near the display unit or
the main unit.
• Take care when storing the display unit. Your
fingers may be trapped between the grip and the
main unit if you press it too strongly.
• Do not use batteries not specified for this unit. Do
not insert the batteries with the polarities in the
wrong direction.
(3) Portable electronic medical devices such as an
electrocardiograph.
This unit could cause these devices to malfunction,
posing a considerable health risk to users of these
devices.
EN
Warning:
• Replace worn batteries with new ones immediately.
• Do not dispose of batteries in fire.
• Never start weight reduction or exercise therapy
without the instructions of a doctor or specialist.
• Do not use the unit on slippery surfaces, such as a
wet floor.
• Keep the unit out of the reach of young children.
• Do not jump onto the unit, or hop up and down on
the unit.
• Do not use this unit when your body and/or feet are
wet, such as after taking a bath.
• Stand on the main unit bare-footed. Attempting to
stand on it with socks on may cause you to slip and
result in injury.
• If battery fluid should get on your skin or clothing,
immediately rinse with plenty of clean water.
• Remove the batteries from this unit when you are
not going to use it for a long period of time
(approximately three months or more).
• Do not use different types of batteries together.
• Do not use new and worn batteries together.
• Remove the display unit from main unit before
stepping on the unit. If you try to remove the display
unit while stepping on to the unit, you may lose your
balance and fall.
• Do not step on the edge or display area of the main
unit.
• People with disabilities, or who are physically frail,
should always be assisted by another person when
using this unit. Use a handrail or so when stepping
on the unit.
Read and follow the “Important information regarding
Electro Magnetic Compatibility (EMC)” in the
Technical Data Section.
1
Useful Information
Principle of body composition calculation
Body fat has low electric conductivity
The BF510 measures the body fat percentage by the Bioelectrical Impedance (BI) method. Muscles, blood vessels
and bones are body tissues with a high water content that conducts electricity easily. Body fat is tissue that has little
electric conductivity. The BF510 sends an extremely weak electrical current of 50 kHz and less than 500 µA through
your body to determine the amount of fat tissue. This weak electrical current is not felt while operating the BF510.
In order for the scale to determine body composition, it uses the electrical impedance, along with your height,
weight, age and gender information to generate results based on OMRON’s data of body composition.
Measures the whole body to avoid the influence of fluctuations
During the course of a day, the amount of water in the body tends to gradually shift to the lower limbs. This is why
there is a tendency for the legs and ankles to swell in the evening or at night. The ratio of water in the upper body
and lower body is different in the morning and evening, and this means that the electrical impedance of the body
also varies. Since the BF510 uses electrodes for both hands and feet to take measurements, it can reduce the
influence of these fluctuations on measurement results.
Recommended measurement times
Understanding the normal changes in your body fat percentage can help you in preventing or reducing obesity.
Being aware of the times when the body fat percentages shift within your own daily schedule will assist you in
obtaining an accurate trending of your body fat. It is recommended to use this unit in the same environment and
daily circumstances. (See chart)
Daily activities
Waking up
Recommended time
Breakfast
After waking up
2 hours
Before lunch and about 2 hours or
more after breakfast
Recommended time
Lunch
2 hours
In the afternoon about 2 hours or
more after lunch and before taking
a bath or eating dinner
Recommended time
Taking a bath or
eating dinner
Avoid measurement immediately
after eating or bathing.
2 hours
Before going to bed and about 2
hours or more after dinner or bath
Recommended time
Going to bed
Avoid taking measurements under the following conditions
If a measurement is made under these physical conditions, the estimated body fat percentage may differ
significantly from the actual one because the water content in the body is changing.
Avoid taking measurements:
- immediately after vigorous exercise
Please wait for 2 hours or more
- after a bath or sauna
- after drinking alcohol
- after drinking lots of water
- after eating a meal
2
Useful Information
What is BMI (Body Mass Index)?
BMI uses the following simple formula to indicate the ratio between weight and height of a person.
BMI = weight (kg) / height (m) / height (m)
The OMRON BF510 uses the height information stored in your personal profile number or when entering
information in the Guest Mode to calculate your BMI classification.
If the fat level revealed by BMI is higher than the international standard, there is an increased likelihood of common
diseases. However, not all types of fat can be revealed by BMI.
What is Body Fat Percentage?
Body fat percentage refers to the amount of body fat mass in regards to the total body weight expressed as a
percentage.
Body fat percentage (%) = {Body fat mass (kg) / Body weight (kg)} × 100
Our device uses BI method to estimate your body fat percentage.
Depending on where fat is distributed in the body, it is classified as visceral fat or subcutaneous fat.
What is Visceral Fat Level?
Visceral fat = fat surrounding internal organs
Too much visceral fat is thought to be closely linked to increased levels of fat in the
bloodstream, which can lead to common diseases such as hyperlipidemia and diabetes,
which impairs the ability of insulin to transfer energy from the bloodstream and using it in
cells. In order to prevent or improve conditions of common diseases, it is important to try
and reduce visceral fat levels to an acceptable level. People with high visceral fat levels
Sample Visceral Fat
(MRI image)
tend to have large stomachs. However, this is not always the case and high visceral fat
levels can lead to metabolically obese. Metabolically obese (visceral obesity with normal
weight) represents fat levels that are higher than average, even if a person’s weight is at
or below the standard for their height.
What is Subcutaneous Fat?
Subcutaneous fat = fat below the skin
Subcutaneous fat not only accumulates around the stomach but also around the upper
arms, hips and thighs, and can cause a distortion of the body's proportions. Although not
directly linked to increased risk of disease, it is thought to increase pressure on the heart
and other complications. Subcutaneous fat is not displayed in this unit, but is included in
the body fat percentage.
Sample Subcutaneous
EN
Fat (MRI image)
What is Skeletal Muscle?
Muscle is divided into two types, muscle in internal organs, such as the heart, and skeletal muscle attached to
bones that is used to move the body. Skeletal muscle can be increased through exercise and other activity.
Increasing the ratio of skeletal muscle means that body can burn energy more easily, which means that it is less
likely to turn to fat, and makes it easier to lead an energetic lifestyle.
The reason calculated results may differ from actual body fat percentage
The body fat percentage measured by this unit may significantly differ from the actual body fat percentage in
the following situations:
Elderly people / People with a fever / Body builders or highly trained athletes / Patients undergoing dialysis /
Patients with osteoporosis who have very low bone density / Pregnant women / People with swelling
These differences may be related to changing ratios of body fluid and/or body composition.
3
Operating instructions
1. Know Your Unit
Display Unit
Grip Electrodes
Display
Up/Down Buttons
Buttons
SET/MODE Button
GUEST Button
USER Button
Cord
Display Unit Holder
Front View
Foot Electrodes
Heel Electrodes
Power Switch
Main Unit (Measurement Platform)
2. Inserting and Replacing the Batteries
1. Open the battery cover on the back of
3. Close the battery cover.
the main unit.
Battery Life and Replacement
1) Press the tab of the battery cover to
release it.
When the battery low indicator (
) appears,
2) Pull it up as shown.
replace all four batteries with new ones.
Items stored in memory are retained even if the
batteries are removed.
Tab
• Replace the batteries after turning off the power.
• Disposal of used batteries should be carried out
in accordance with the national regulations for
the disposal of batteries.
• Four AA batteries will last approximately 1 year
(when measurements are made four times a
day).
• Because the supplied batteries are for trial use
only, they may have a shorter life.
2. Install the batteries in correct polarity
as marked inside the battery
compartment.
4
3. Setting and Storing Personal Data
For the measurement of body fat percentage, visceral fat level and skeletal muscle percentage, it is necessary to
set your personal data (age, gender, height).
1. Turn on the power.
3. [TO SET THE AGE]
“CAL” blinks on the
display, then the
display changes to
“0.0 kg”.
Setting range: 10 to 80 years old
1) Press the
or
button to
adjust the age.
* Wait until “0.0 kg” is displayed.
2. Press the USER
button to select
your personal
2) Press the SET/
MODE button to
confirm.
Then the gender
icons blink on the
display.
profile number.
1) The selected
number blinks on
the display.
4. [TO SET THE GENDER AND
HEIGHT]
Set the gender (MALE) or (FEMALE) and
height in the same way.
2) Press the SET/
MODE button to
confirm.
Then the default
age setting blinks
on the display.
After all the settings are displayed for your
confirmation, “0.0 kg” appears on the display.
This completes the setting.
Selecting Measurement Unit
You can change the measurement units used for the height and weight settings.
1. Turn on the power.
3. Press the
button to select “kg” or
“lb”.
“CAL” blinks on the display, then the display
changes to “0.0 kg”.
Wait until “0.0 kg” appears on the display.
EN
This will also automatically change “cm” and
“in”.
2. Keep the
button pressed until “lb”
and “kg” blink on the display.
4. Press the SET/MODE button to
confirm.
All height and weight measurements are displayed
using the new measurement units. The change
remains in effect until you change it again.
5
3.Setting and Storing Personal Data
Changing the Personal Data
1. Turn on the power.
3. With the
or
button, modify the
selected item, followed by pressing
SET/MODE button. The display will
change in order of age, gender and
height.
“CAL” blinks on the display, then the display
changes to “0.0 kg”.
Wait until “0.0 kg” appears on the display.
2. Press the USER button to select
your personal profile number.
1) Your number flashes one time on the
display.
2) Press the SET/
MODE button
to confirm.
Then the
selected age
setting blinks
on the display.
Deleting the Personal Data
1. Turn on the Power.
3. Delete the personal data.
“CAL” blinks on the display, then the display
changes to “0.0 kg”.
Press the GUEST
button for more
Wait until “0.0 kg” appears on the display.
than two seconds.
“Clr” will appear on
the display and the
personal data are
deleted from memory.
2. Press the USER button to select
your personal profile number.
1) Your number flashes one time on the
display.
2) Press the SET/
MODE button
to confirm.
Then the
selected age
setting blinks
on the display.
Power Switch
The power will automatically switch off in the following conditions:
1. If the monitor is not used within one minute of “0.0 kg” appearing on the display.
2. If no information is entered for 5 minutes when entering personal data.
3. If the monitor is not used for 5 minutes after the measurement results are displayed.
4. Five (5) minutes after the result is displayed when measuring weight only.
6
4. Taking a Measurement
Measurement should be taken on a level and hard surface.
1. Turn on the power.
4. Start measurement.
“CAL” blinks on the
display, then the
display changes to “0.0
kg”.
1) Step on the main unit and place your feet
on the foot electrodes with your weight
evenly distributed.
* If you step onto the unit before “0.0 kg”
appears on the display, an error message
“Err” will appear.
The display will show your weight and then the
weight result will blink twice.
The unit will then start to measure your body fat
percentage, visceral fat level and skeletal muscle
percentage.
2. When the “0.0 kg” is displayed, take
out the display unit.
2) When “START” appears on the display,
extend your arms straight at a 90° angle
to your body.
Note: Do not take out the display unit until
“0.0 kg” appears on the display.
Otherwise, the weight of the display is
add to your body weight which causes
an incorrect result.
3. Select the personal profile number.
Press the USER button while holding the
display unit. Selected number will appear after
blinking once.
If the following display is indicated:
The indicators in the measurement progress bar at
the bottom of the display will gradually appear,
from left to right.
3) After the measurement
is complete, your
Your personal data is not stored in the personal
profile number you have selected. Please see
Section 3 to store personal data.
weight is displayed
again. At this point you
may step off the unit.
If you do not have personal data
stored on the unit (GUEST
mode):
EN
1) Press the GUEST button while
holding the display unit.
2) The GUEST indication “G” appears
on the display.
3) Set the personal data (age, gender,
and height). Read steps 3 through
4 in Section 3, Setting and Storing
Personal Data.
7
4.Taking a Measurement
Correct Posture for Measurement
(2)
The arms are horizontally raised, and
the elbows are extended straight.
After measuring
your weight.
Extend your arms straight at a 90°
angle to your body.
90°
(3)
Hold the display unit so that you can
see the display.
(1)
Stand with your knees
and back straight and
look straight ahead.
Press your palms firmly on the grip
electrodes.
Step on the main unit bare-footed.
Place your middle
Hold the inner grip
electrodes firmly with
your thumb and
index finger.
Hold the outer grip
fingers in the dent
at the back of the
grip electrodes.
electrodes with your
ring finger and small
finger.
Heel Electrodes
• Make sure each of your heels is
positioned on a heel electrode. Stand
with your weight evenly distributed on
the measurement platform.
Postures to Avoid During Measurement
Movement during
measurement
Arms bent
Arms too low or
high
Display facing
upwards
Knees bent
Standing on edge
of unit
8
4.Taking a Measurement
5. Check the measurement results.
Press the SET/MODE button to view the desired measurement results. The display changes with each press
of the SET/MODE button as follows: FAT -> VISCERAL FAT -> BMI -> MUSCLE -> WEIGHT (again)
Body Fat Percentage
Skeletal Muscle Percentage
Body Fat Percentage
Classification
Skeletal Muscle Percentage
Classification
Visceral Fat Level
BMI
Visceral Fat Level
Classification
BMI Classification
Interpreting the Body Fat Percentage Result
Gender
Age
Low (–)
< 21.0%
< 23.0%
< 24.0%
< 8.0%
< 11.0%
< 13.0%
Normal (0)
21.0 - 32.9%
23.0 - 33.9%
24.0 - 35.9%
8.0 - 19.9%
11.0 - 21.9%
13.0 - 24.9%
High (+)
Very High (++)
_
_
>
33.0 - 38.9%
34.0 - 39.9%
36.0 - 41.9%
20.0 - 24.9%
22.0 - 27.9%
25.0 - 29.9%
20 - 39
39.0%
40.0%
42.0%
25.0%
28.0%
30.0%
_
_
>
Female 40 - 59
60 - 79
_
_
>
_
_
>
20 - 39
_
_
>
Male
40 - 59
60 - 79
_
_
>
Based on NIH/WHO guidelines for BMI
Based on Gallagher et al., American Journal of Clinical Nutrition, Vol. 72, Sept. 2000
EN
Interpreting the Visceral Fat Level Result
Visceral Fat Level
1 - 9
Level Classification
0 (Normal)
+ (High)
10 - 14
++ (Very High)
15 - 30
According to Omron Healthcare figures
9
5.Measuring Weight Only
Interpreting the BMI Result
BMI Classification Bar
BMI Rating
BMI (Designation by the WHO)
BMI
7.0 - 10.7
10.8 - 14.5
14.6 - 18.4
- (Underweight)
0 (Normal)
BMI < 18.5
18.5 - 20.5
20.6 - 22.7
22.8 - 24.9
_
_
>
18.5 < BMI < 25
25.0 - 26.5
26.6 - 28.2
28.3 - 29.9
_
_
>
+ (Overweight)
++ (Obese)
25 < BMI < 30
30.0 - 34.9
35.0 - 39.9
40.0 - 90.0
_
_
>
30 < BMI
The above-mentioned indices refer to the values for obesity judgment proposed by WHO, the World Health Organization.
Interpreting the Skeletal Muscle Percentage Result
Gender
Age
Low (–)
< 24.3%
< 24.1%
< 23.9%
< 33.3%
< 33.1%
< 32.9%
Normal (0)
24.3 - 30.3%
24.1 - 30.1%
23.9 - 29.9%
33.3 - 39.3%
33.1 - 39.1%
32.9 - 38.9%
High (+)
Very High (++)
_
_
>
30.4 - 35.3%
30.2 - 35.1%
30.0 - 34.9%
39.4 - 44.0%
39.2 - 43.8%
39.0 - 43.6%
18-39
40-59
60-80
18-39
40-59
60-80
35.4%
35.2%
35.0%
44.1%
43.9%
43.7%
_
_
>
Female
_
_
>
_
_
>
_
_
>
Male
_
_
>
According to Omron Healthcare figures
6. After confirmation of the results, turn off the power.
Note: If you forget to turn off the power, the unit will be turned off automatically after 5 minutes.
5. Measuring Weight Only
1. Turn on the power.
3. Check the measurement result.
“CAL” blinks on the
display, then the
display changes to “0.0
kg”.
Your weight is displayed and blinks twice to
indicate that measurement is completed.
Note: You can also check the measurement
result by taking out the display unit.
* If you step onto the
unit before “0.0 kg”
appears on the
display, an error
message “Err” will
appear.
4. When the measurement is completed,
step down from the unit and turn off
the power.
2. When the “0.0 kg” is displayed, step
onto the unit.
Note: Leave the display unit in the display
unit holder.
10
6. Error Displays
Error Display
Cause
Correction
Press your palms or soles firmly to the
electrodes, then measure. (Refer to Section
4.)
Your palms or soles are not in firm contact
with the electrodes.
The posture for measurement is wrong or
the palms or soles are not in firm contact
with the electrodes.
Measure without moving the hands or soles.
(Refer to Section 4.)
Moisten the palms or soles with a wet towel,
then repeat measurement.
The palms or soles are too dry.
• Please ensure that age, gender and height
settings stored as personal data are
correct (see Setting Items in Section 9).
• The main unit cannot measure body
composition outside its measurement
range, even if the Age, Gender and Height
settings are correct.
Values of body composition are out of
measurable range.
Insert the batteries again and repeat
measurement.
Abnormal operation.
If this error still occurs, consult your
OMRON service representative.
You stepped on the unit before the display
indicated “0.0 kg”.
Step on the main unit after the display
indicates “0.0 kg”.
You moved the main unit before the display Do not move the main unit until the display
indicated “0.0 kg”.
indicates “0.0 kg”.
You moved your body while measuring body
weight.
Do not move while measuring body weight.
Body weight of 150 kg (330.0 lb) or over is
out of the measuring range of this unit. You
cannot use this unit.
Your weight is 150 kg (330.0 lb) or over.
7. Troubleshooting
EN
Problem
Cause
Correction
The displayed value of body
composition is abnormally high or
low.
Refer to “Useful Information”.
The power turns off approximately 5
minutes after the body weight is
confirmed and before your body fat
percentage, visceral fat level and
skeletal muscle percentage is
measured.
You did not select the correct
personal profile number or the
GUEST mode. (The personal profile number or the GUEST mode. (Refer
number or “G” is not displayed on
the display unit.)
Select the correct personal profile
to Section 4.)
Batteries are not inserted.
Insert the batteries.
The polarities of batteries are not
aligned correctly.
Insert the batteries in correct
alignment.
Nothing is displayed when the
power is turned on.
Replace all four batteries with new
ones. (Refer to Section 2.)
The batteries are worn out.
The cord connecting the main unit
and the display unit is damaged or
worn.
Contact the nearest OMRON
service representative.
11
Care and maintenance
8. How to Take Care of and Store the Unit
How to Clean the Unit
• Always keep the unit clean before use.
• Wipe the main unit with a soft dry cloth.
If necessary, use a cloth moistened with water or detergent and squeeze it well before wiping the unit, then wipe
dry with a dry cloth.
• You can use rubbing alcohol to clean the electrodes, but do not use it on other parts of the unit.
• Do not use benzene or thinner, to clean the unit.
Care and Storage
• Store the display unit in the main unit as shown.
• When storing the display unit, be careful not to crease the cord.
• Do not store the unit in the following conditions:
- Humidity, where moisture or water may get into the unit
- High temperatures, direct sunlight or dusty places
- Places with the risk of sudden shocks or vibrations
- In places where chemicals are stored or where corrosive gas is present.
• Do not carry out repairs of any kind yourself. If a defect occurs, consult the OMRON distributor or Customer
Services as mentioned on the packaging.
12
9. Technical Data
Name
BF510
Product
Model
Body Composition Monitor
HBF-510-E
Display
Body Weight:
0 to 150 kg with an increment of 0.1 kg
(0.0 to 330.0 lb with an increment of 0.2 lb)
5.0 to 60.0% with an increment of 0.1%
5.0 to 50.0% with an increment of 0.1%
7.0 to 90.0 with an increment of 0.1
30 levels with an increment of 1 level
Body Fat percentage:
Skeletal Muscle percentage:
BMI:
Visceral Fat Level:
BMI classification:
– (Underweight) / 0 (Normal) / + (Overweight) / ++ (Obese) with 12 levels of Bar display
Body fat percentage and Skeletal muscle percentage classification:
– (Low) / 0 (Normal) / + (High) / ++ (Very High) with 12 levels of Bar display
Visceral fat level classification:
0 (Normal) / + (High) / ++ (Very High) with 9 levels of Bar display
Height: 100.0 to 199.5 cm (3' 4" to 6' 6 3/4")
Age: 10 to 80 years old
Setting Items
Gender: Male/Female
* Measurement Units: kg (cm) / lb (feet•inch)
*The age range for the skeletal muscle percentage, skeletal muscle percentage
classification, visceral fat level and visceral fat level classification is 18 to 80
years old.
*The age range for the body fat percentage classification is 20 to 79 years old.
Weight Accuracy
Accuracy (S.E.E.)
0.0 kg to 40.0 kg:
(0.0 lb to 88.2 lb:
±
0.4 kg
±
0.88 lb)
40.0 kg to 150.0 kg:
±
±
1%
(88.2 lb to 330.0 lb:
1%)
Body Fat percentage:
Skeletal Muscle percentage:
Visceral Fat Level:
3.5%
3.5%
3 levels
Power Supply
Battery Life
4 AA batteries (R6) (You may also use AA alkaline batteries (LR6).)
Approximately 1 year (when manganese batteries are used with four measurements
a day)
Operating Temperature /
Humidity
+10°C to +40°C, 30% to 85% RH
Storage Temperature/
Humidity/Air Pressure
-20°C to +60°C, 10% to 95% RH, 700 hPa - 1060 hPa
Approximately 2.2 kg (4.85 lb) (including batteries)
EN
Weight
External Dimensions
Display unit:
Approx. 300 (W) × 35 (H) × 147 mm (D)
(Approx. 11 3/4" (W) x 1 3/8" (H) x 5 3/4" (D))
Approx. 303 (W) × 55 (H) × 327 mm (D)
(Approx. 11 7/8" (W) x 2 1/8" (H) x 12 7/8" (D))
Main unit:
Package Contents
Body Composition Monitor, 4 AA manganese batteries (R6), instruction manual,
Guarantee Card
Note:
Subject to technical modification without prior notice.
= Type BF
Please read the instruction manual carefully before using the device.
13
9.Technical Data
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
This marking shown on the product or its literature, indicates that it should not be disposed with other
household wastes at the end of its working life. To prevent possible harm to the environment or human health
from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to
promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government
office, for details of where and how they can take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This
product should not be mixed with other commercial wastes for disposal.
This product does not contain any hazardous substances.
Disposal of used batteries should be carried out in accordance with the national regulations for the disposal of
batteries
Important information regarding Electro Magnetic Compatibility (EMC)
With the increased number of electronic devices such as PCs and mobile (cellular) telephones, medical
devices in use may be susceptible to electromagnetic interference from other devices.
Electromagnetic interference may result in incorrect operation of the medical device and create a potentially
unsafe situation.
Medical devices should also not interfere with other devices.
In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with the aim of preventing
unsafe product situations, the EN60601-1-2 standard has been implemented. This standard defines the levels
of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for
medical devices.
This medical device manufactured by OMRON Healthcare conforms to this
EN60601-1-2:2001 standard for both immunity and emissions.
Nevertheless, special precautions need to be observed:
Do not use mobile (cellular) telephones and other devices, which generate strong electrical or electromagnetic
fields, near the medical device. This may result in incorrect operation of the unit and create a potentially unsafe
situation. Recommendation is to keep a minimum distance of 7 m.
Verify correct operation of the device in case the distance is shorter.
Further documentation in accordance with EN60601-1-2:2001 is available at OMRON Healthcare Europe at the
address mentioned in this instruction manual.
14
OMRON HEALTHCARE CO., LTD.
24, Yamanouchi Yamanoshita-cho, Ukyo-ku, Kyoto,
615-0084 Japan
Manufacturer
OMRON HEALTHCARE EUROPE B.V.
Kruisweg 577, 2132 NA Hoofddorp, The Netherlands
EU-representative
EC
REP
OMRON HEALTHCARE UK LTD.
Opal Drive
Fox Milne, Milton Keynes MK15 0DG, United Kingdom
OMRON Medizintechnik Handelsgesellschaft mbH
John-Deere-Str. 81a, 68163 Mannheim, Germany
Subsidiary
OMRON SANTÉ FRANCE SAS
14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, France
Made in China
|
Milwaukee Saw 6177 20 User Manual
Navman GPS Receiver Smart 2005 User Manual
Nortel Networks Server NN43001 100 User Manual
Northern Network Card UTA220 UTA220k User Manual
Nostalgia Electrics Frozen Dessert Maker SCM 502 User Manual
Oki Printer 407II User Manual
Oster Coffeemaker 137264 User Manual
Oster Food Processor 4 CUP MINI FOOD PROCESSOR User Manual
Panasonic Electric Shaver ER422 User Manual
Panasonic Fax Machine KX FL611AL User Manual